fetal radiation doses in pregnancy Xrays and CT scans

see also:

Introduction

  • lead shielding for patients is no longer recommended
  • the benefits even for pregnant woman are neglible - radiation from scatter from the body far exceeds any benefit from the shielding 1)

Estimated threshold radiation doses for fetal injury

gestation threshold radiation dose (mGy)
congenital anomalies or growth restriction during organogenesis (4-10wks gestation) 200
intellectual disability 10-17wks gestation 60-310
intellectual disability 18-27wks gestation 250-280

Estimated fetal doses

modality est. fetal dose (mGy)
CXR / head Xray <0.0001
AXR 0.1-3.0
CT head 1-10
CT chest/liver or CTPA 0.01-0.7
CT abdomen 1-10
CT abdo pelvis 10-50
V/Q scan 0.1-0.5

NB. external lead shielding of maternal pelvis reduces radiation dose by ~3% at all stages of pregnancy 3)

maternal risks of radiation exposure

3)
Circulation 2001; 104:893-7, Damilakus et al